MasterLine 8 Panel Door
Technical informationPerformance
Energy
- Thermal insulation - Uf
- 1.4 W/m²K
- Uw Dependencies
- Single inward opening door: Up 0.6W/m²K, @1.23x2.18m, 36mm panel
- Thermal insulation - Ud
- 1 W/m²K
Comfort
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class 7A (300Pa)
- Wind load resistance
- Class C2 (800Pa)
- Opening & closing resistance
- Class 8
Safety
- Burglar resistance
- RC2 - RC3
Properties
Max. dimensions & weight
- Min. height of vent
- 500 mm
- Max. height of vent
- 3000 mm
- Min. width of vent
- 500 mm
- Max. width of vent
- 1400 mm
- Max. weight of vent
- 250 kg
Sightlines
- Min. frame width (inward opening)
- 68.5 mm
- Min. vent width (inward opening)
- 0 mm
- Min. frame-vent width (inward opening)
- 68.5 mm
- Min. frame width (outward opening)
- 42.5 mm
- Min. vent width (outward opening)
- 0 mm
- Min. frame-vent width (outward opening)
- 42.5 mm
- Min. height treshold
- 0 mm
- Depth frame
- 77 mm
- Depth Vent
- 77 mm
- Depth frame-vent
- 77 mm
Glazing
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - Structural Glued Glazing
- Min. glass thickness - frame/element
- 6 mm
- Max. glass thickness - frame/element
- 63 mm