Skip to main content

ConceptSystem 77 Smoke & Heat Evacuation

Technical information

Performance

Energy

Thermal insulation - Uf
1.8 W/m²K
Thermal insulation - Uw
1.3 W/m²K
Uw Dependencies
Frame-vent HI: Ug 1.0W/m²K, warm edge spacer,@1.23x1.48m (102mm sight line), 36mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class C5 (2000Pa)
Acoustics - Rw(C;Ctr)
42(-2;-4) dB
Opening & closing resistance
Class 3

Safety

Burglar resistance
PAS 24 - RC2 - RC3
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
1700 mm
Max. height of vent
2400 mm
Min. width of vent
1200 mm
Max. width of vent
1400 mm

Sightlines

Min. frame width (inward opening)
64 mm
Min. vent width (inward opening)
46 mm
Min. frame-vent width (inward opening)
110 mm
Min. vent-vent width (inward opening)
144 mm
Min. width T-profile
76 mm
Depth frame
68 mm
Depth Vent
77 mm
Depth frame-vent
77 mm

Glazing

Rebate height
25 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - frame/element
4 mm
Max. glass thickness - frame/element
52 mm
Min. glass thickness - vent
4 mm
Max. glass thickness - vent
63 mm